Home
Catalog
Medical Equipment
Infusion equipment
Surgical tables
Sterilizers
Medical ventilators
Rehabilitation Products
Laboratory refrigerators
Anesthesiology and Reanimation
Electrosurgery
View all
Medical Supplies
Instruments and Supplies for Medical Personnel
Various Instruments and Supplies for Anesthesiology and Resuscitation Services
Instrument Sets and Individual Surgical Instruments
Medical Gloves
Syringes
Sterilization Pouches
Disposable Medical Supplies
View all
Medical Furniture
Patient Room Furniture
Medical cabinets and carts
Dental Furniture
Hospital Beds
Hemodialysis Chairs
Stretchers
Medical mattresses
Wheelchairs
Hospital furniture
Surgical tables
View all
Medical Instruments
Reagents
Other
Medication
About us
Contacts
English
Հայերեն
English
Русский
1
"/>
0
Cart
Loading...
Total
0
Checkout
English
Հայերեն
English
Русский
Home
Medical Equipment
Anesthesiology and Reanimation
Patient Monitor PH-PM-003
Patient Monitor PH-PM-003
Add
Description
Technical Parameters
Display & General:
12.1-inch non-touchscreen TFT display
Resolution: 800 × 600 (high resolution)
Multi-language support (8 languages, including Chinese & English)
Standard parameters: SpO₂, ECG, PR, NIBP, Respiration, Temperature
Standard ECG: 5-lead cable
Built-in battery: 2000 mAh
Includes adult accessories set
Physical Characteristics:
Net weight: 2.72 kg
Device size: 262 × 336 × 84 mm
Package size: 380 × 350 × 300 mm
Operating temperature: 0 – 40 °C
Working humidity: ≤ 85%
ECG:
Lead configuration: 6-pin, 5-lead
Gain settings: ×0.25, ×0.5, ×1, ×2, ×4, automatic
Heart rate (Adults): 1 – 300 bpm
Heart rate (Neonatal/Pediatric): 15 – 350 bpm
Electrode polarization voltage: ±300 mV
Respiration:
Measurement method: RA-LL impedance
Respiration rate (Adults): 0 – 120 BrPM
Respiration rate (Pediatric/Neonatal): 7 – 120 BrPM
Apnea alarm: 10 – 40 seconds
SpO₂ & Pulse:
SpO₂ range: 0 – 100%
Accuracy: ±2% (70–100%)
Pulse rate: 30 – 300 bpm
Resolution: 1 bpm
Accuracy: ±3 bpm
Non-Invasive Blood Pressure (NIBP):
Modes: Manual / Automatic / Continuous
Auto interval: 1 – 480 minutes
Pulse rate range: 30 – 300 bpm
Measurement range:
Systolic: 40 – 270 mmHg
Diastolic: 10 – 215 mmHg
Mean: 20 – 235 mmHg
Static pressure range: 0 – 300 mmHg
Accuracy: ±3 mmHg
Temperature:
Measurement range: 0 – 50 °C
Accuracy: ±0.1 °C
Similar products
Anesthesiology and Reanimation
Infusion Pump PH-50
Add
Anesthesiology and Reanimation
Patient Monitor with Defibrillator COMEN S2
Add
Anesthesiology and Reanimation
Patient Monitor PH-PM-002
Add
Anesthesiology and Reanimation
Anesthesia Workstation PH-AM-001
Add
Anesthesiology and Reanimation
Anesthesia Machine / Anesthesia Workstation PH-AM-002
Add
Anesthesiology and Reanimation
Patient Monitor PH-PM-001
Add
Anesthesiology and Reanimation
Ventilator PH-V-001
Add
Anesthesiology and Reanimation
Patient Monitor YONKER YK-8000C
Add
Anesthesiology and Reanimation
Patient Monitor PH-PM-8000C
Add
Syringes
Sterile 3-Piece Syringe with Needle, 10 ml
Add